Fabric OS Message Reference

53-1002749-01

IPS-1004

5

IPS-1004

Message

Port Config Mode Mismatch slot (<slot>) port(ge<port>): current mode is (<current
mode>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that configured port mode is different from the intended use.

Recommended

Action

Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the port
mode to neutral before attempting to configure the port for a different mode or use.

IPS-1005

Message

Tunnel Authorization Failure for slot (<slot>) port(ge<port>) tunnel ID(<tunnel
number>) reason (<reason>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that tunnel setup failed because of an authorization failure from the remote side. A reason for
such a failure could be a WWN mismatch.

Recommended

Action

Change the tunnel configuration on one side of the tunnel to authorize the remote side to set up the
tunnel.

IPS-1006

Message

Tunnel Configuration Mismatch for slot (<slot>) port(<port>) tunnel ID(<tunnel
number>) reason (<reason>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that tunnel setup failed because of a configuration mismatch between the two ends. The
reason field indicates the cause for configuration mismatch.

Recommended

Action

Change the tunnel configuration on one side of the tunnel to match that of the other side to set up the
tunnel.

Advertising