Fabric OS Message Reference

53-1002749-01

SEC-1321

5

SEC-1321

Message

Failed secure mode enable command. Reason: <Reason>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the security enable failed on the fabric because the switch has a conflicting configuration such
as fabric-wide consistency configuration or AD configuration.

Recommended

Action

Verify the security event was planned. If the security event was planned, run the fddCfg --fabwideset
command or ad --clear command to clear the fabric wide consistency configuration or AD configuration
and retry the secModeEnable command.

SEC-1322

Message

Some DCC policy is too large, distribution cancelled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates this fabric is not able to support a Device Connection Control (DCC) policy with more than 256
ports.

Recommended

Action

Reconfigure any policy that includes more than 256 ports in its member list, and then save the policy
configuration changes.

SEC-1323

Message

Key(s) \"<Key Name>\" ignored during configdownload.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the specified key is ignored during configuration download.

Recommended

Action

Verify the event was planned. If the event was planned, no action is required. If the event was not
planned, take appropriate action as defined by your enterprise security policy.