Ps messages, Ps-1000, Ps-1001 – Dell POWEREDGE M1000E User Manual

Page 682: Ps-1002

Advertising
background image

660

Fabric OS Message Reference

53-1002749-01

PS-1000

5

PS Messages

PS-1000

Message

Failed to initialize Advanced Performance Monitoring.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that an unexpected software error has occurred in Advanced Performance Monitoring. The
Performance Monitor has failed to initialize.

Recommended

Action

The control processor (CP) will reboot or failover automatically. If it does not, reboot or power cycle the
switch to reinitiate the firmware.

PS-1001

Message

Advanced Performance Monitoring configuration updated due to change in PID format.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the port ID (PID) format was changed.

Recommended

Action

No action is required. Refer to the Fabric OS Administrator's Guide for more information about the PID
format.

PS-1002

Message

Failed to initialize the tracing system for Advanced Performance Monitoring.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that an unexpected software error has occurred in Advanced Performance Monitoring. The
Performance Monitor tracing system has failed to initialize.

Recommended

Action

Tracing will not be available for Advanced Performance Monitoring, but other functions will function
normally. To activate tracing, reboot or failover the control processor (CP).

Advertising