Fw-1010, Fw-1011, Fw-1012 – Dell POWEREDGE M1000E User Manual

Page 463

Advertising
background image

Fabric OS Message Reference

441

53-1002749-01

FW-1010

5

FW-1010

Message

<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the power supply is faulty. The power supply is not producing enough power.

Recommended

Action

Verify that you have installed the power supply correctly and that it is correctly seated in the chassis. If
the problem persists, replace the faulty power supply.

FW-1011

Message

<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the power supply is functioning properly.

Recommended

Action

Set the high boundary above the normal operation range.

FW-1012

Message

<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the power supply counter changed from a value outside of the acceptable range to a value
within the acceptable range.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

Advertising