Ficn-1006, Ficn-1007, Ficn-1008 – Dell POWEREDGE M1000E User Manual

Page 397

Advertising
background image

Fabric OS Message Reference

375

53-1002749-01

FICN-1006

5

FICN-1006

Message

FICON GEPort <GE port number> TID <Tunnel number> Feature Change failed Xrc <1 or
0 - XRC Emulation Enabled or Disabled> TapeWrt <1 or 0 - Tape Write Emulation
Enabled or Disabled> TapeRd <1 or 0 - FICON Tape Read Emulation Enabled or
Disabled> TinTir <1 or 0 - FICON TIN/TIR Emulation Enabled or Disabled> DvcAck <1
or 0 - FICON Device Level Ack Emulation Enabled or Disabled> RdBlkId <1 or 0 -
FICON Write Emulation Read Block ID Emulation Enabled or Disabled>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the feature change has failed because the FCIP tunnel ID associated with the FICON
tunnel is still active.

Recommended

Action

Disable the applicable FCIP tunnel to make the feature change effective.

FICN-1007

Message

DevDiskEgr:FICON Selective Reset:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> State=0x<Current Emulation
State> stat_array=0x<the Last 4 Status values that were received from the device>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a Selective Reset from the channel was received as either a normal part of path recovery or the
starting sequence in an error case.

Recommended

Action

If there was a job failure associated with this event, contact your vendor's customer support.

FICN-1008

Message

DevDiskEgr:FICON Purge Path received Path=0x<VEPortNumber HostDomain HostPort
DeviceDomcontactain><DevicePort LPAR CUADDR DeviceAddr>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a FICON Purge Path was received from the channel as a part of path recovery.

Recommended

Action

If there was a job failure associated with this event, contact your vendor's customer support for
assistance.

Advertising