Fabric OS Message Reference

283

53-1002749-01

EM-1017

5

EM-1017

Message

Uncommitted WWN change detected. Cold reboot required.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a user did not commit a changed World Wide Name (WWN) value before performing a
system restart, power cycle, or firmware download operation.

Recommended

Action

Change and commit the new WWN value.

EM-1018

Message

CP blade in slot <slot number> failed to retrieve current chassis type (<return
code>/<error code>/0x<unit number>).

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that there was a failure to read the chassis type from the system.

Recommended

Action

Verify that the control processor (CP) blade is operational and is properly seated in its slot.

EM-1019

Message

Current chassis configuration option (<Chassis config option currently in effect>)
is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the current chassis configuration option is not supported by the firmware on the standby
control processor (CP). This is true even if the standby CP comes up and is operational. High availability
(HA) synchronization of the CPs will not be allowed.

Recommended

Action

Change the chassis configuration option to 1 using the chassisConfig command, or upgrade the
firmware on the standby CP to the version running on the active CP.