Nsm-1003, Nsm-1004, Nsm-1005 – Dell POWEREDGE M1000E User Manual

Page 656: Nsm-1006

Advertising
background image

634

Fabric OS Message Reference

53-1002749-01

NSM-1003

5

NSM-1003

Message

Interface <InterfaceName> is link down.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified interface has gone offline because the link is down.

Recommended

Action

Check whether the connectivity between the peer ports is proper, and the remote link is up using the
show interface command.

NSM-1004

Message

Interface <InterfaceName> is created.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified logical interface has been created.

Recommended

Action

No action is required.

NSM-1005

Message

The FCoE VLAN: <VlanName> is in use. Therefore, cannot disable the FCoE VLAN.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified Fibre Channel over Ethernet (FCoE) VLAN is used in the FCoE daemon
(fcoed) and therefore cannot be disabled.

Recommended

Action

Remove all the FCoE sessions from the FCoE VLAN member ports and then disable the FCoE VLAN.

NSM-1006

Message

FCoE on VLAN: <VlanName> has been disabled successfully.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that FCoE has been disabled on the specified VLAN.

Advertising