Fabric OS Message Reference

287

53-1002749-01

EM-1037

5

EM-1037

Message

<FRU Id> is no longer faulted.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified power supply is no longer marked faulty; probably because its AC power
supply has been turned on.

Recommended

Action

No action is required.

EM-1042

Message

Important FRU header data for <FRU Id> is not valid.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU
header-derived information. This could mean that the FRU header was corrupted or read incorrectly, or
corrupted in the object database, which contains information about all FRUs.

Recommended

Action

Reseat the FRU. If the problem persists, replace the FRU.

EM-1043

Message

Can't power <FRU Id> <state (on or off)>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified field-replaceable unit (FRU) cannot be powered on or off.

Recommended

Action

The specified FRU is not responding to the commands and should be replaced.