Fabric OS Message Reference

407

53-1002749-01

FICN-1100

5

FICN-1100

Message

HostTeraIng:FICON Selective Reset:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> Elapsed Time=<the number of
seconds since the last IO started for this device>.<the number of milliseconds
since the last IO started for this device> seconds.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that protocol errors in emulation in the Control Unit or network errors can cause Selective
Reset.

Recommended

Action

If this was an unexpected event, contact your vendor's customer support for assistance.

FICN-1101

Message

HostTeraIng:FICON Purge received:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a Purge Path was received from the locally connected FICON channel. This is performed
during the path recovery.

Recommended

Action

If this was an unexpected event, contact your vendor's customer support for assistance.

FICN-1102

Message

HostTeraIng:LRJ received on Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> lastCmds=0x<Last 4 commands
received from the channel for this device> lastStatus=0x<Last 4 status values
presented to the channel for this device> treating as system reset event.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a Link Level Reject (LRJ) from a FICON channel indicates that the channel believes that it no
longer has a path established to the Control Unit.

Recommended

Action

This is normally an unexpected event; contact your vendor's customer support for assistance.