Ps-1006, Ps-1007, Ps-1008 – Dell POWEREDGE M1000E User Manual

Page 684

Advertising
background image

662

Fabric OS Message Reference

53-1002749-01

PS-1006

5

PS-1006

Message

Failed to add fabricmode toptalker monitors on domain=<domain id>, because
end-to-end monitors are configured on this switch.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that end-to-end monitors are configured on the switch.

Recommended

Action

Delete end-to-end monitors on the switch and re-install the fabric mode Top Talker monitor. End-to-end
monitors and fabric mode Top Talker monitors are mutually exclusive.

PS-1007

Message

Failed to add Fabricmode Top Talker on domain=<domain id>. <function name>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that FC Routing (FCR) is enabled on the specified fabric.

Recommended

Action

Top Talker cannot be installed on a fabric with FCR service enabled. In case Top Talker must be installed
on a fabric, disable FCR using the fosconfig --disable fcr command.

PS-1008

Message

Failed to delete fabricmode Top Talker monitor on domain <domain id>, Failure
reason: <error code>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the fabric is not stable, the domain is not reachable, or the resource is not available.

Recommended

Action

Wait for the fabric to become stable and then execute the perfttmon --delete fabricmode command.