Fss-1004, Fss-1005, Fss-1006 – Dell POWEREDGE M1000E User Manual

Page 455

Advertising
background image

Fabric OS Message Reference

433

53-1002749-01

FSS-1004

5

FSS-1004

Message

Memory shortage.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the system ran out of memory.

Recommended

Action

Execute the memShow command to view memory usage in the switch.

For a dual CP system, enable the high availability (HA) state synchronization using the haSyncStart
command. For non-bladed systems, restart the switch using the reboot command.

If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

FSS-1005

Message

FSS read failure.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the read system call to the Fabric OS state synchronization (FSS) device has failed.

Recommended

Action

If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

FSS-1006

Message

No FSS message available.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that data is not available on the Fabric OS state synchronization (FSS) device.

Recommended

Action

If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

Advertising