Ecc messages, Ecc-1000, Ecc-1001 – Dell POWEREDGE M1000E User Manual

Page 299

Advertising
background image

Fabric OS Message Reference

277

53-1002749-01

ECC-1000

5

ECC Messages

ECC-1000

Message

ECC Error <Multiple or single occurrence of errors of a given type detected>
occurrence of <Automatic calibration error detected><Multiple bit error
detected><Single bit error detected><Memory select error detected>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the processor memory controller has detected one of the several types of double data rate
(DDR) memory errors. Single bit errors are corrected, but other errors indicate either software errors or
problems with the target system DRAM. Single bit errors can be expected to occur infrequently and can
be caused by uncontrollable external events like cosmic rays, but frequent single bit errors can be
indications of a degrading DRAM device.

Recommended

Action

Frequent single bit errors and all other error types should be reported to technical support for further
action.

ECC-1001

Message

ECC Error <Multiple or single occurrence of multiple bit ECC error
detected><Multiple or single occurrence of single bit ECC error detected><Multiple
of single occurrence of access outside the defined physical memory space detected>
detected.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the processor memory controller has detected one of the several types of double data rate
(DDR) memory errors. Single bit errors are corrected, but other errors indicate either software errors or
problems with the target system DRAM. Single bit errors can be expected to occur infrequently and can
be caused by uncontrollable external events like cosmic rays, but frequent single bit errors can be
indications of a degrading DRAM device.

Recommended

Action

Frequent single bit errors and all other error types should be reported to technical support for further
action.