PLAT-1000

Message

<Function name> <Error string>.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that nonrecoverable peripheral component interconnect (PCI) errors have been detected.

Recommended

Action

The system will be faulted and may automatically reboot.

If the system does not reboot automatically, reboot the system manually using the reboot command.

Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.

PLAT-1001

Message

CP<Identifies which CP (0 or 1) is doing the reset> resetting other CP (double
reset may occur).

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the other control processor (CP) is being reset. This message is typically generated by a CP
that is in the process of becoming the active CP. Note that in certain circumstances a CP may experience
a double reset and reboot twice. A CP can recover automatically even if it has rebooted twice.

Recommended

Action

No action is required.

PLAT-1002

Message

CP<Identifies which CP (0 or 1) is generating the message>: <Error message> CP
Fence 0x<CP Fence register. Contents (2 bytes) are platform-specific> 0x<CP Error
register. Contents are platform-specific> CP Error 0x<Write control flag. Contents
are platform-specific>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the control processor (CP) cannot access the inter-integrated circuit (I2C) subsystem
because of an error condition or because of being fenced or isolated from the I2C bus.

Recommended

Action

Reboot the CP if it does not reboot automatically. Reseat the CP if rebooting does not solve the problem.
If the problem persists, replace the CP.