Bl-1041, Bl-1045, Bl-1046 – Dell POWEREDGE M1000E User Manual

Page 199

Advertising
background image

Fabric OS Message Reference

177

53-1002749-01

BL-1041

5

BL-1041

Message

Dynamic area mode is enabled on default switch, Faulting the blade w/ ID <Blade ID
of blade that has the mini SFP+ that does not support it> in slot <slot number> as
it does not support this mode.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the blade does not support dynamic area mode on the default switch.

Recommended

Action

Turn off the dynamic area mode using the configure command.

BL-1045

Message

mini SFP+ (SN: <mini SFP+ serial number>) is only supported in certain high port
count blades, not blade in slot <slot number of blade that has the mini SFP+> w/
ID <Blade ID of blade that has the mini SFP+ that does not support it>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that mini-SFP+ is supported only by a certain type of blade (FC8-64), but it can be inserted in
other blades.

Recommended

Action

Replace the mini-SFP+ with an SFP or SFP+.

BL-1046

Message

<Slot number of blade that has the SFP> error on SFP in Slot <Port number into
which the SFP is inserted>/Port <The type of error "checksum" or "data access" for
general problems accessing the i2c accessible data> (<A detailed error code>). Try
reseating or replacing it.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the checksum in an area on the small form-factor pluggable (SFP) transceiver does not
match with the computed value, or there is problem accessing the data.

Recommended

Action

Reseat the SFP transceiver. If problem persists, replace the SFP transceiver.

Advertising