Fw-1206, Fw-1207, Fw-1216 – Dell POWEREDGE M1000E User Manual

Page 497

Advertising
background image

Fabric OS Message Reference

475

53-1002749-01

FW-1206

5

FW-1206

Message

<Port Name> <Label> is above high boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the trunk utilization is above its threshold level.

Recommended

Action

Increase the bandwidth by adding more links to the trunk.

FW-1207

Message

<Port Name> <Label> is between high and low boundaries(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the trunk utilization is between the low and high thresholds.

Recommended

Action

No action is required.

FW-1216

Message

<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of Arbitrated Loop Physical Address (ALPA) cyclic redundancy check (CRC)
errors has changed. This indicates that errors have been detected in the FC frame. Invalid CRC
messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID)
and destination ID (D_ID) pairs change. These messages might also be caused by dirty equipment,
temperature fluctuations, and aging equipment. You should set your high boundaries to five- or six-digit
figures, because only large numbers of messages indicate a problem in this area.

Recommended

Action

Verify that your optical components are clean and function properly. Replace deteriorating cables or
small form-factor pluggables (SFPs). Check for damage from heat or age.

Advertising