Plat-1003, Plat-1004, Plat-1072 – Dell POWEREDGE M1000E User Manual

Page 674

Advertising
background image

652

Fabric OS Message Reference

53-1002749-01

PLAT-1003

5

PLAT-1003

Message

<Info message> Slot <Blade Slot number> C/BE: 0x<Captured Command/Byte-Enables
data> ADBUS: 0x<Captured AD bus data> misc_intr 0x<Bridge reset interrupts>.

Message Type

LOG | FFDC

Severity

CRITICAL

Probable Cause

Indicates that peripheral component interconnect (PCI) bus hang was detected.

Recommended

Action

Replace the field-replaceable unit (FRU).

PLAT-1004

Message

Switch has older FPGA rev 0x<FPGA version already installed in HW>. Upgrade to
newer rev 0x<FPGA version which Fabric OS carries> using the fpga_update command.

Message Type

LOG | FFDC

Severity

CRITICAL

Probable Cause

Indicates that Fabric OS has older field-programmable gate array (FPGA) version. This message is
applicable only to Brocade 5470.

Recommended

Action

Upgrade FPGA to new version.

PLAT-1072

Message

The chassis is disabled because no Core Blades are available. Insert/replace one
or both Core Blades and run chassisenable.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the chassis has been disabled because of the unavailability of the core blades. There must
be at least one core blade in enabled state for the chassis to be considered ready. All core blades are
either missing, faulted, or powered off. This results in all logical switches (and ports) being disabled.

Recommended

Action

Make sure that all core blade slots have core blades inserted and their ejector switches are closed.
Power on core blades that are powered off, and power cycle or replace the core blades that are faulted.

Run the chassisenable command to re-enable the ports.

Running the fastboot or reboot command will also result in enabling the logical switches and ports.

Advertising