Cnm-1011, Cnm-1012, Cnm-1013 – Dell POWEREDGE M1000E User Manual

Page 241: Cnm-1014

Advertising
background image

Fabric OS Message Reference

219

53-1002749-01

CNM-1011

5

CNM-1011

Message

Posting event CNM_EVT_NODE_JOIN_TIMEOUT nodeName [<nodeName>], WWN [<wwn>],
ipaddress [<ipAddr>].

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the node join timeout.

Recommended

Action

Take the peer node offline, and rejoin the node to Encryption Group (EG).

CNM-1012

Message

Posting event CNM_EVT_EG_DELETED.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the Encryption Group (EG) is deleted.

Recommended

Action

No action is required.

CNM-1013

Message

Posting event GL Node Split condition, isolating peer GL node <nodeName>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the Encryption Group (EG) is split.

Recommended

Action

No action is required.

CNM-1014

Message

Posting event Node Admission Control passed, admitting node [<nodeName>].

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the node admission control was successful.

Advertising