Fabric OS Message Reference

241

53-1002749-01

CONF-1024

5

CONF-1024

Message

configUpload failed <Message>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a configUpload operation has failed.

Recommended

Action

Execute the errShow command to view the error log. Correct the error and execute the configUpload
command again.

CONF-1030

Message

Configuration database full, data not committed (key: <Key of failed configuration
data>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the previous configuration commands have resulted in a database full
condition.Configuration changes associated with the specified key was not applied.

Recommended

Action

Use configure command and various other commands to erase configuration parameters that are no
longer required. As a last resort, execute the configDefault command and reconfigure the system.

CONF-1031

Message

configDefault completed successfully <Message>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the configDefault command was initiated and completed successfully.

Recommended

Action

No action is required.