Ssmd-1204, Ssmd-1205, Ssmd-1206 – Dell POWEREDGE M1000E User Manual

Page 836

Advertising
background image

814

Fabric OS Message Reference

53-1002749-01

SSMD-1204

5

SSMD-1204

Message

QoS failed initializing ASIC <ASIC slot number>/<ASIC chip number>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in initializing the dataplane ASIC QoS
infrastructure.

Recommended

Action

Restart or power cycle the switch.

SSMD-1205

Message

CEE failed programming ETS policy for CEE Map <CEE Map name>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the Converged Enhanced Ethernet (CEE) Map Enhanced Transmission Selection (ETS)
feature.

Recommended

Action

Delete and reapply the CEE Map ETS policy using the cee-map default command.

If the problem persists, restart or power cycle the switch.

SSMD-1206

Message

CEE failed programming CoS to PGID policy for CEE Map <CEE Map name>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the CEE Map Class of Service (CoS) to Priority Group ID (PGID) mapping feature.

Recommended

Action

Delete and reapply the CEE Map CoS to PGID policy using the cee-map default command.

If the problem persists, restart or power cycle the switch.

Advertising