Fabric OS Message Reference

53-1002749-01

BL-1025

5

BL-1025

Message

All GigE/FCIP/Virtualization/FC Fastwrite ports on the blade in slot <slot number>
will be reset as part of the firmware upgrade.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the
cold upgrade. As part of the upgrade, all the Gigabit Ethernet, Fibre Channel over IP (FCIP),
virtualization data elements, and FC Fastwrite ports were reset.

Recommended

Action

No action is required.

BL-1026

Message

Internal port offline during warm recovery, state <port state> (0x<port ID>).

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that an internal port went offline during warm recovery of the switch. The switch will reboot and
start cold recovery.

Recommended

Action

Execute the supportSave command and then reboot switch. If the problem persists, replace the switch.

BL-1027

Message

Blade in slot <slot number> faulted, boot failed; status 0x<boot status> 0x<1250 0
boot status> 0x<1250 1 boot status>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the blade failed to boot properly.

Recommended

Action

Reboot or power cycle the blade using the slotPowerOff and slotPowerOn commands.

If the message persists, replace the blade.