Hil-1403, Hil-1404, Hil-1501 – Dell POWEREDGE M1000E User Manual

Page 579

Advertising
background image

Fabric OS Message Reference

557

53-1002749-01

HIL-1403

5

HIL-1403

Message

All fan FRUs missing. Install fan FRUs immediately.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that all fan field-replaceable units (FRUs) have been removed.

Recommended

Action

Install the missing fan FRUs immediately.

HIL-1404

Message

<count> fan FRUs missing. Install fan FRUs immediately.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one or more fan field-replaceable units (FRUs) have been removed.

Recommended

Action

Install the missing fan FRUs immediately.

HIL-1501

Message

Slot <slot number>, high temperature (<measured temperature>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the temperature of this blade has risen above the warning threshold.

Recommended

Action

Run the fanShow command to verify all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational range of
your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.

Advertising