Sysm messages, Sysm-1001, Sysm-1002 – Dell POWEREDGE M1000E User Manual

Page 876: Sysm-1003

Advertising
background image

854

Fabric OS Message Reference

53-1002749-01

SYSM-1001

5

SYSM Messages

SYSM-1001

Message

No memory.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates the switch has run out of system memory.

Recommended

Action

Run the memShow command to view the switch memory usage.

Reboot or power cycle the switch.

Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

SYSM-1002

Message

<number>, Switch: <Switch number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a user has executed either the switchShutdown or switchReboot command. All services are
brought down for a logical switch.

Recommended

Action

No action is required if the switchShutdown or switchReboot command was executed intentionally. If
the switchShutdown command was run, you must run the switchStart command to restart traffic on the
logical switch.

SYSM-1003

Message

<number>, Switch: <start reason>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the user executed the switchStart or switchReboot command. All services are brought back
up after a temporary shutdown of the logical switch.

Recommended

Action

No action is required if the switchStart command was executed intentionally. Because reinitializing a
switch is a disruptive operation and can stop I/O traffic, you may have to stop and restart the traffic during
this process.

Advertising