Fcoe-1029, Fcoe-1030, Fcoe-1031 – Dell POWEREDGE M1000E User Manual

Page 357: Fcoe-1032

Advertising
background image

Fabric OS Message Reference

335

53-1002749-01

FCOE-1029

5

FCOE-1029

Message

Version mismatch between FIP FDISC and root VN port.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a version mismatch between the fabric login (FLOGI) and FDISC.

Recommended

Action

It is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance.

FCOE-1030

Message

Version mismatch between FIP LOGO and root VN port.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a version mismatch between the FCoE initialization protocol (FIP) logout and the base fabric
login (FLOGI).

Recommended

Action

It is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance.

FCOE-1031

Message

FCoE port deleted port <port> slot <slot>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that an FCoE port has been deleted.

Recommended

Action

No action is required.

FCOE-1032

Message

We are in WARM RECOVERING state...

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that high availability (HA) failover or switch reboot may be in progress.

Advertising