Zone-1026, Zone-1027 – Dell POWEREDGE M1000E User Manual

Page 918

Advertising
background image

896

Fabric OS Message Reference

53-1002749-01

ZONE-1026

5

ZONE-1026

Message

port <port number> Out of CAM entries.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the total number of entries of S_ID CAM is above the limit while creating or adding a zone
group. The maximum number of CAM entries allowed depends on the application-specific integrated
circuit (ASIC).

Recommended

Action

If hardware zoning enforcement is preferred, edit the zoning database to have zoned port IDs (PIDs) for
that port.

ZONE-1027

Message

Zoning transaction aborted <error reason>. <AD Id>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the zoning transaction was aborted because of a variety of potential errors. The error reason
variable can be one of the following conditions:

Zone Merge Received: The fabric is in the process of merging two zone databases.

Zone Config update Received: The fabric is in the process of updating the zone database.

Bad Zone Config: The new configuration is not viable.

Zoning Operation failed: A zoning operation failed.

Shell exited: The command shell has exited.

Unknown: An error was received for an unknown reason.

User Command: A user aborted the current zoning transaction.

Switch Shutting Down: The switch is currently shutting down.

Most of these error conditions are transitory.

Recommended

Action

Try again after some time. Verify that only one administrator is modifying with the zone database at a
time.

Advertising