Ficu-1013, Ficu-1017, Ficu-1018 – Dell POWEREDGE M1000E User Manual

Page 444

Advertising
background image

422

Fabric OS Message Reference

53-1002749-01

FICU-1013

5

FICU-1013

Message

Host data file cannot be reset to proper size.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the file system is too full to create the host data file at the proper size.

Recommended

Action

Execute the switchStatusShow command to check if the flash memory is full. If the flash memory is full,
execute the supportSave command to clear the core files.

FICU-1017

Message

FMSMODE enable failed because reserved area is bound to a device.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one or both of the reserved areas 0xFE and 0xFF is bound to a device.

Recommended

Action

Execute the wwnaddress --show command to display all devices currently bound to areas. Execute the
wwnaddress --unbind command to release the reserved area from the device.

FICU-1018

Message

FMSMODE enable noticed swapped ports.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that some ports are swapped at the time FICON Management Server mode (fmsMode) is
enabled.

Recommended

Action

Verify the expected FICON port address and port number relationship. For more information, refer to the
"FICON and FICON CUP in Virtual Fabrics" section of the FICON Administrator's Guide.

Advertising