Fabric OS Message Reference

53-1002749-01

FW-1432

5

FW-1432

Message

Switch status change contributing factor WWN: <Number Bad> bad.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the switch is not in a healthy state. This occurred because the number of faulty World Wide
Name (WWN) cards is greater than or equal to the policy set by the switchStatusPolicySet command.

Recommended

Action

Replace the faulty WWN card.

FW-1433

Message

Switch status change contributing factor CP: CP non-redundant (<CP Number>)
faulty.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the switch is not in a healthy state. This occurred because the number of faulty CPs is
greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are not
redundant.

If you power cycle a chassis in dual-domain configuration, and then reset the micro-switch of the active
CP before the heartbeat is up, this will cause both CPs to come up in a non-redundant state.

Recommended

Action

Execute the firmwareShow command to verify if both the CPs have compatible firmware levels. Execute
the firmwareDownload command to install the same level of firmware to both CPs. Replace any faulty
CPs.

If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on
a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the
problem.

FW-1434

Message

Switch status change contributing factor Blade: <Number Bad> blade failures
(<Blade Numbers>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the switch is not in a healthy state. This occurred because the number of blade failures is
greater than or equal to the policy set by the switchStatusPolicySet command.

Recommended

Action

Replace the faulty blade.