L2ss-1004, L2ss-1005, L2ss-1006 – Dell POWEREDGE M1000E User Manual

Page 613

Advertising
background image

Fabric OS Message Reference

591

53-1002749-01

L2SS-1004

5

L2SS-1004

Message

FDB error: Error in creating AVL tree.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Layer 2 system (L2SYS) has encountered an error while initializing the AVL tree.

Recommended

Action

Reboot or power cycle the switch.

L2SS-1005

Message

MAC-address-table hash failed even after two attempts for slot <slot> chip <chip>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the media access control (MAC) address table hash failed even after two hash changes on
the specified chip.

Recommended

Action

Reboot or power cycle the switch.

L2SS-1006

Message

MAC-address-table table on slot <Slot_id> chip <Chip_id> is 95 percent full.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the media access control (MAC) address table on the chip is 95 percent full.

Recommended

Action

Clear some of the entries using the no mac-address-table static command or wait until the old entries
age out.

Advertising