Fcr-1004, Fcr-1005, Fcr-1006 – Dell POWEREDGE M1000E User Manual

Page 368

Advertising
background image

346

Fabric OS Message Reference

53-1002749-01

FCR-1004

5

FCR-1004

Message

FC router physical devices offline at port <port number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that one or more physical devices connected to the specified port have gone offline.

Recommended

Action

Verify that the devices were intended to be taken offline. If not, verify that the devices are functioning
properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check for faulty cables,
deteriorated SFPs, or dirty connections. Replace the cables and the SFPs if necessary.

FCR-1005

Message

FC router LSAN zone device removed at port <port number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a device is removed from the logical storage area network (LSAN) zone in the edge fabric.

Recommended

Action

No action is required.

FCR-1006

Message

FC router LSAN zone device added at port <port number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a device is added to a logical storage area network (LSAN) zone in the edge fabric.

Recommended

Action

No action is required.