Bl-1019, Bl-1020, Bl-1021 – Dell POWEREDGE M1000E User Manual

Page 192

Advertising
background image

170

Fabric OS Message Reference

53-1002749-01

BL-1019

5

BL-1019

Message

Slot <Slot number>, retry <Retry Number>, internal port retry initialization,
<List of internal ports retrying initialization>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the slot had internal ports that are not online. Initiated a retry on ports that failed to go
online.

Recommended

Action

No action is required.

BL-1020

Message

Switch timed out initializing the chips.

Message Type

LOG | FFDC

Severity

CRITICAL

Probable Cause

Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC) chips.

Recommended

Action

Reboot or power cycle the switch. If the message persists, replace the switch.

BL-1021

Message

Retry <Retry Number>, internal port retry initialization, <List of internal ports
retrying initialization>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the switch had internal ports that are not online. Initiated a retry on ports that failed to go
online.

Recommended

Action

No action is required.

Advertising