Fabric OS Message Reference

835

53-1002749-01

SULB-1020

5

SULB-1020

Message

New firmware failed to boot in slot <Slot number>.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

ERROR

Probable Cause

Indicates that the BP blade is still running the old image even though it should reboot with the new image.
This error may indicate that the new image has not been loaded correctly to the specified blade.

Recommended

Action

Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and slotPowerOn
commands to trigger another firmware download to the blade. If the blade is stuck in LOADING state,
remove and re-insert the blade to trigger another firmware download. If the problem persists, contact
your switch service provider.

SULB-1021

Message

Firmware is being downloaded to the blade in slot <Slot number>.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

WARNING

Probable Cause

Indicates that the firmware is being loaded to the specified blade.

Recommended

Action

Run the firmwareDownloadStatus command to monitor the firmware download progress. After it
finishes, run the firmwareShow command to verify the firmware versions.

SULB-1022

Message

The blade in slot <Slot number> has rebooted successfully with new firmware.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the blade in the specified slot has rebooted with new firmware. This is a normal step in the
firmware download process.

Recommended

Action

Run the firmwareDownloadStatus command to monitor the firmware download progress.