332

Fabric OS Message Reference

53-1002749-01

FCOE-1019

5

Recommended

Action

Disable the active FCoE session on VLAN using the no fcoe command and try adding the FCMAP
again.

FCOE-1019

Message

FLOGI ignored as FCMAP is not configured on FCoE VLAN.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that FCMAP has not been configured on FCoE VLAN.

Recommended

Action

Configure FCMAP on the FCoE VLAN using the fcoe --fcmapset command.

FCOE-1021

Message

Port is already logged in.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the N_Port device has already logged in or is in the process; duplicate FLOGI received.

Recommended

Action

No action is required.

FCOE-1022

Message

Max FCoE device login limit reached.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the switch has reached its maximum allowed FCoE device limit.

Recommended

Action

Do not add any more FCoE devices to the switch.