Ucst-1024, Ucst-1026, Ucst-1027 – Dell POWEREDGE M1000E User Manual
Page 892
870
Fabric OS Message Reference
53-1002749-01
UCST-1024
5
UCST-1024
Message
Dynamic Load Sharing option has been disabled.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that Dynamic Load Sharing (DLS) option has been disabled on the switch.
Recommended
Action
No action is required.
UCST-1026
Message
LossLess-DLS option has been enabled.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that the NoFrameDrop option has been enabled. This will help minimize frame loss during
fabric topology changes.
Recommended
Action
No action is required.
UCST-1027
Message
LossLess-DLS option has been disabled.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that the NoFrameDrop option has been disabled. This may cause higher frame loss during
fabric topology changes.
Recommended
Action
No action is required.