Fabric OS Message Reference

341

53-1002749-01

FCPD-1001

5

FCPD Messages

FCPD-1001

Message

Probing failed on <error string>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a Fibre Channel Protocol (FCP) switch probed devices on a loop port, and probing failed
on the L_Port, arbitrated loop physical address (AL_PA), or the F_Port. For ALPA, the valid range is 0x00
through 0xFF. The error variable can be either of the following:

L_Port

port_number

ALPA

alpa_number

F_Port

port_number

This could happen due to some firmware issue with the device controller on the specified port.

Recommended

Action

Contact the device vendor for any firmware-related issues. Also, consider upgrading the device firmware.

FCPD-1002

Message

port <port number>, bad R_CTL for fcp probing: 0x<R_CTL value>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the response frame received on the specified port for an inquiry request contains an invalid
value in the routing control field. This could happen due to some firmware issue with the device controller
on the specified port.

Recommended

Action

Contact the device vendor for any firmware-related issues. Also, consider upgrading the device firmware.

FCPD-1003

Message

Probing failed on <error string> which is possibly a private device which is not
supported in this port type.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that device probing has failed because private devices will not respond to the switch port login
(PLOGI) during probing.