Fabric OS Message Reference

53-1002749-01

FICN-1009

5

FICN-1009

Message

DevIng:CmdReject Sense Data rcvd:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> LastCmds=0x<the Last 4 commands
issued to the device> Sense Data:Bytes0-0xB=0x<bytes 0-3 of sense data from the
device><bytes 4-7 of sense data from the device><bytes 8-0x0b of sense data from
the device>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a Unit Check status was received from a device and a sense command was issued to read the
sense data.

Recommended

Action

If there was a job failure associated with this event, contact your vendor's customer support for
assistance.

FICN-1010

Message

DevDiskEgr:Device level exception flag found for Path=0x<VEPortNumber HostDomain
HostPort DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>: Oxid=0x<The OXID that
was reported in the Device Level Exception Frame>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a Device Level Exception frame was received from the FICON channel.

Recommended

Action

If there was a job or I/O failure associated with this event, contact your vendor's customer support for
assistance.

FICN-1011

Message

DevDiskIng:XRC Incorrect RRS SeqNum Rcvd Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> Expected=0x<The RRS Sequence
number that was expected from the device> Received=0x<The RRS Sequence number that
was actually received from the device> Oxid=0x<The data frame's OXID>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the Control unit or device presented a Read Record Set Sequence number different from the
SDM's expected sequence number.

Recommended

Action

If there was an XRC volume or session suspended associated with this event, contact your vendor's
customer support for assistance.