Fabric OS Message Reference

53-1002749-01

AG-1039

5

AG-1039

Message

F_Port <Port that was reset> was reset because a WWN mapped device using it,
through N_Port <Port who's state change caused the reset>, went offline.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified F_Port was reset because an N_Port went offline and the changes need to be
propagated to all involved devices.

Recommended

Action

No action is required. This port reset was not an error.

AG-1040

Message

PID of the devices connected to Port <port number> may have changed, as the port
was toggled. Check EE monitor configuration as it might not be functional.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that N_Port ID virtualization (NPIV) assigns a new port ID (PID) each time the same port is
disabled and then re-enabled. As the PID has changed, the end-to-end (EE) monitors installed with the
previous PID stops functioning.

Recommended

Action

Install new EE monitors with the new PID of the port to be monitored by using the perfAddEEMonitor
command.

AG-1041

Message

Static F_Ports mapped to N_Port <port number> are disabled as Trunking is enabled
on the N_Port.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a trunk is enabled on the specified N_Port, and therefore the F_Port static mapping is
disabled.

Recommended

Action

Delete static mapping on the Access Gateway using the ag --staticdel command or disable the trunk on
the N_Port using the switchCfgTrunkPort command.