Fabric OS Message Reference

145

53-1002749-01

AUTH-1004

5

AUTH-1004

Message

Failed to set <data type> type to <setting value>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the authUtil command has failed to set the authentication configuration value. The data
type
can be authentication type, DH group type, hash type, or policy type.

Recommended

Action

Execute the authUtil command again.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

AUTH-1005

Message

Authentication file does not exist: <error code>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an authentication file corruption.

Recommended

Action

Execute the firmwareDownload command to reinstall the firmware.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

AUTH-1006

Message

Failed to open authentication configuration file.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates an internal problem with the Secure Fabric OS.

Recommended

Action

Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.