Fcoe-1026, Fcoe-1027, Fcoe-1028 – Dell POWEREDGE M1000E User Manual

Page 356

Advertising
background image

334

Fabric OS Message Reference

53-1002749-01

FCOE-1026

5

FCOE-1026

Message

FDISC/FLOGI mismatch. FDISC addressed to different FCF than base FLOGI.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the base port has sent a fabric login (FLOGI) but the subsequent FDISC frames that were
received on the switch do not match the original FLOGI.

Recommended

Action

It is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance.

FCOE-1027

Message

<message> : <mac1>:<mac2>:<mac3>:<mac4>:<mac5>:<mac6>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Fibre Channel Forwarders (FCF) controller is not found for the DA. The end node may
be sending the FLOGI with a wrong DA MAC address.

Recommended

Action

Some parameters are not exchanged correctly between the switch and the end device. Reconfigure the
port.

FCOE-1028

Message

<message> : <wwn1>:<wwn2>:<wwn3>:<wwn4>:<wwn5>:<wwn6>:<wwn7>:<wwn8>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the FCoE device with the specified World Wide Name (WWN) is not a member of the login
group.

Recommended

Action

Change the FCoE login group policy on the switch using the fcoelogingroup command so that the
device can log in.

Advertising