Ficu-1010, Ficu-1011, Ficu-1012 – Dell POWEREDGE M1000E User Manual

Page 443

Advertising
background image

Fabric OS Message Reference

421

53-1002749-01

FICU-1010

5

FICU-1010

Message

FMS mode enable failed due to port(s) with areas 0xFE or 0xFF is(are) connected to
device(s).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the FICON Management Server (FMS) mode was not enabled because ports with areas
0xFE or 0xFF are connected to devices.

Recommended

Action

Disable ports with areas 0xFE or 0xFF using the portDisable command.

FICU-1011

Message

FMS mode has been enabled.

Message Type

AUDIT | LOG

Class

CFG

Severity

INFO

Probable Cause

Indicates that the FICON Management Server mode (fmsMode) has been enabled.

Recommended

Action

No action is required.

FICU-1012

Message

FMS mode has been disabled.

Message Type

AUDIT | LOG

Class

CFG

Severity

INFO

Probable Cause

Indicates that the FICON Management Server mode (fmsMode) has been disabled.

Recommended

Action

No action is required.