Fabr-1018, Fabr-1019, Fabr-1020 – Dell POWEREDGE M1000E User Manual

Page 332

Advertising
background image

310

Fabric OS Message Reference

53-1002749-01

FABR-1018

5

FABR-1018

Message

PSS principal failed (<reason for not becoming the principal switch>: <WWN of new
principal switch>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a failure occurred when trying to set the principal switch using the fabricPrincipal
command. The message notifies you that the switch failed to become the principal switch because of one
of the following reasons:

The switch joined an existing fabric and bypassed the F0 state.

The fabric already contains a principal switch that has a lower World Wide Name (WWN).

Recommended

Action

Make sure that no other switch is configured as the principal switch. Force a fabric rebuild by using the
switchDisable and switchEnable commands.

Refer to the Fabric OS Command Reference for more information about the fabricPrincipal command.

FABR-1019

Message

Critical fabric size (<current domains>) exceeds supported configuration
(<supported domains>).

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a
specified limit to the number of domains. This limit is defined by your specific value-line license key. The
fabric size has exceeded this specified limit, and the grace period counter has started. If the grace period
is complete and the size of the fabric is still outside the specified limit, Web Tools is disabled.

Recommended

Action

Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size of the
fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric
license.

FABR-1020

Message

Web Tools will be disabled in <days> days <hours> hours and <minutes> minutes.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that this switch has a value-line license and has a limited number of domains. If more than the
specified number of domains are in the fabric, a counter is started to disable Web Tools. This message
displays the number of days left in the grace period. After this time, Web Tools is disabled.

Advertising