BM-1007

5

Recommended

Action

Configure the blade so that it will persistently enable the ports.

BM-1007

Message

If set, clear EX/VEX/FC Fastwrite configuration for all ports for blade in slot
<Slot number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the specified blade was detected for the first time after an FR4-18i was previously configured in
the same slot. The new blade requires the specified port configurations to be cleared.

Recommended

Action

No action is required. The blade ports are cleared automatically.

BM-1008

Message

Download of blade firmware failed for blade in slot <slot>. Reissue
firmwaredownload to recover.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the automatic firmware upgrade on the blade failed because the blade firmware version
was detected to be different from the control processor (CP) firmware version.

Recommended

Action

Execute the firmwareDownload command to recover the blade.

BM-1009

Message

Firmwaredownload timed-out for application processor. Faulting switch.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the firmware download on the application processor (AP) blade failed.

Recommended

Action

Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade.