Sec-1173, Sec-1174, Sec-1175 – Dell POWEREDGE M1000E User Manual

Page 751

Advertising
background image

Fabric OS Message Reference

729

53-1002749-01

SEC-1173

5

SEC-1173

Message

Lost contact with Primary FCS switch.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the switch has lost contact with the primary fabric configuration server (FCS) switch in the
secure fabric. This could result from the primary FCS being disabled.

Recommended

Action

If the primary FCS was disabled intentionally, no action is required; if not, check the primary FCS.

SEC-1174

Message

Failed to set <FCS or non-FCS> password.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the fabric configuration server (FCS) or non-FCS password could not be set.

Recommended

Action

Verify all switches in the fabric are in time synchronization with the primary FCS and that no external
entity is trying to access the fabric. When verification is complete, retry the operation.

SEC-1175

Message

Failed to install zone data.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the zone database could not be installed on the switch.

Recommended

Action

Verify all switches in the fabric are in time synchronization with the primary FCS and that no external
entity is trying to access the fabric. When verification is complete, retry the operation.