Sulb-1038, Sulb-1039, Sulb-1040 – Dell POWEREDGE M1000E User Manual

Page 862

Advertising
background image

840

Fabric OS Message Reference

53-1002749-01

SULB-1038

5

SULB-1038

Message

Co-CPU has not booted up properly. Skip the firmwaredownload command on the
co-CPU.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

WARNING

Probable Cause

Indicates that the main CPU cannot access the co-CPU to update the firmware on the co-CPU or run any
other firmware download command on the co-CPU. If the firmwareDownload command is in progress, it
will continue without updating the co-CPU firmware.

Recommended

Action

After the firmware download completes, reboot the CP manually to bring up the co-CPU and run the
firmwareDownload command again. If the problem persists, your switch service provider.

SULB-1039

Message

CP has completed relocating the internal firmware image.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

INFO

Probable Cause

Indicates that the firmware download process has completed normally on the control processor (CP).

Recommended

Action

Run the firmwareShow command to verify the firmware versions.

SULB-1040

Message

An error has occurred during relocation of the internal image on the CP.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

WARNING

Probable Cause

Indicates that an error has occurred during the relocation of the internal image. The error may be caused
by an inconsistent internal firmware image. It may also be caused by an internal Ethernet failure.

Recommended

Action

Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload
command again if the firmware is not updated.

This will cause the internal image to be relocated again. If the problem persists, contact your switch
service provider.

Advertising