Cvlm-1011, Cvlm-1012, Cvlm-1013 – Dell POWEREDGE M1000E User Manual

Page 283

Advertising
background image

Fabric OS Message Reference

261

53-1002749-01

CVLM-1011

5

CVLM-1011

Message

The HAC failover occurs at EE (<EE node WWN> <EE slot num>).

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the HA cluster (HAC) failover occurs at the encryption engine.

Recommended

Action

No action is required.

CVLM-1012

Message

The HAC failback occurs at EE (<EE node WWN> <EE slot num>).

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the HA cluster (HAC) failback occurs at the encryption engine.

Recommended

Action

No action is required.

CVLM-1013

Message

Redirect zone create failed because no Host/Target
(<HostPortWWN>/<TargetPortWWN>) L2 zone exists.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that creation of the redirect zone has failed.

Recommended

Action

Create the Layer 2 zone for host and target and run the cryptocfg --commit command again.

Advertising