Bl-1037, Bl-1038, Bl-1039 – Dell POWEREDGE M1000E User Manual

Page 198

Advertising
background image

176

Fabric OS Message Reference

53-1002749-01

BL-1037

5

BL-1037

Message

Faulting chip in slot = <slot number>, miniS = <miniS number>,port = <port number>
due to BE/BI port fault.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that all ports on the chip have been disabled due to a fault on the chip.

Recommended

Action

Make sure that the blade is seated correctly.

If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.

Additional blade fault messages precede and follow this error, providing more information. Refer to other
error messages for recommended action.

If the message persists, replace the blade.

BL-1038

Message

Inconsistent FPGA image version detected, please reboot the switch for recovery.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the field-programmable gate array (FPGA) image version is incompatible with the software
version.

Recommended

Action

Reboot the switch. If the message persists, replace the switch.

BL-1039

Message

Inconsistent FPGA image version detected, faulting the blade in slot <slot
number>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the field-programmable gate array (FPGA) image version is incompatible with the software
version.

Recommended

Action

Power cycle the blade using the slotPowerOff and slotPowerOn commands.

If the message persists, replace the blade.

Advertising