Fabric OS Message Reference

443

53-1002749-01

FW-1036

5

FW-1036

Message

<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the temperature of the small form-factor pluggable (SFP) has changed from a value
outside of the acceptable range to a value within the acceptable range. Frequent fluctuations in
temperature may indicate a deteriorating SFP.

Recommended

Action

No action is required.

FW-1037

Message

<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The
receive performance area measures the amount of incoming laser to help you determine whether the
SFP is in good working condition. If the counter often exceeds the threshold, the SFP is deteriorating.

Recommended

Action

Incoming laser fluctuations usually indicate a deteriorating SFP. If the message persists, replace the SFP.

FW-1038

Message

<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the receive power value of the small form-factor pluggable (SFP) has fallen below the low
boundary. The receive performance area measures the amount of incoming laser to help you determine
whether the SFP is in good working condition. If the counter often exceeds the threshold, the SFP is
deteriorating.

Recommended

Action

Verify that your optical components are clean and function properly. Replace deteriorating cables or
SFPs. Check for damage from heat or age.