Bl-1007, Bl-1008, Bl-1009 – Dell POWEREDGE M1000E User Manual

Page 187

Advertising
background image

Fabric OS Message Reference

165

53-1002749-01

BL-1007

5

BL-1007

Message

blade #<blade number>: blade state is inconsistent with EM. bl_cflags 0x<blade
control flags>, slot_on <slot_on flag>, slot_off <slot_off flag>, faulty <faulty
flag>, status <blade status>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a failover occurred while a blade was initializing on the previously active control processor
(CP).

Recommended

Action

No action is required. The blade is reinitialized. Because reinitializing a blade is a disruptive operation
and can stop I/O traffic, you may need to stop and restart the traffic during this process.

BL-1008

Message

Slot <slot number> control-plane failure. Expected value: 0x<value 1>, Actual:
0x<value 2>.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the blade has experienced a hardware failure or was removed without following the
recommended removal procedure.

Recommended

Action

Make sure that the blade is seated correctly.

If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.

If the message persists, replace the blade.

BL-1009

Message

Blade in slot <slot number> timed out initializing the chips.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the blade has failed to initialize the application-specific integrated circuit (ASIC) chips.

Advertising