832

Fabric OS Message Reference

53-1002749-01

SULB-1009

5

The following descriptions explain the causes of some common error messages:

0x15 - "Failed to download RPM package." If this error occurs immediately after firmware
download is started, the firmware on the switch may be two releases older than the requested
firmware. The firmware download operation supports firmware upgrades within two feature
releases (a feature release is indicated by a major number and a minor number; for example,
X.Y). In this case, you will need to upgrade to an intermediate version before downloading the
desired version. If this error occurs in the middle of a firmware download, the firmware in the
file server may be corrupted or there may be a temporary network issue. In this case, retry the

firmwareDownload

command. If the problem persists, contact your system administrator.

0x18 - "Error in getting lock device for firmware download". This error can be due to another
firmware download is already in progress. Run the

firmwareDownloadStatus

command to

verify that this is the case. Wait for the current session to finish before proceeding.

0x23 - "Firmware download timed out." This error may occur because the

firmwareDownloadStatus

command has not completed within the predefined timeout period.

It is most often caused by network issues. If the problem persists, contact your system
administrator.

0x24 - "Out of disk space." This error may occur because some core dump files have not been
removed from the filesystem and are using up disk space. Remove these core dump files by
using the

supportSave

command before proceeding.

0x29 - "The pre-install script failed." This error may be caused by an unsupported blade type.
Remove or power off the unsupported blades before proceeding.

0x2e - "Invalid RPM package." This error may be caused by an inconsistent firmware image
loaded on the file server. It may also be caused by temporary networking issues. Reload the
firmware packages on the file server and then retry the

firmwareDownload

command. If the

problem persists, contact your system administrator.

The following table lists the

firmwareDownload

state names and code values. They indicate where

in the

firmwareDownload

process the error occurred.

TABLE 9

Upgrade state and code value

Upgrade state

Code

SUS_PEER_CHECK_SANITY

0x21

SUS_PEER_FWDL_BEGIN

0x22

SUS_SBY_FWDL_BEGIN

0x23

SUS_PEER_REBOOT

0x24

SUS_SBY_REBOOT

0x25

SUS_SBY_FABOS_OK

0x26

SUS_PEER_FS_CHECK

0x27

SUS_SELF_FAILOVER

0x28

SUS_SBY_FWDL1_BEGIN

0x29

SUS_SELF_FWDL_BEGIN

0x2a

SUS_SELF_COMMIT

0x2b

SUS_SBY_FWC_BEGIN

0x2c

SUS_SBY_COMMIT

0x2d

SUS_SBY_FS_CHECK

0x2e

Advertising