Fw messages, Fw-1001, Fw-1002 – Dell POWEREDGE M1000E User Manual

Page 460: Fw-1003

Advertising
background image

438

Fabric OS Message Reference

53-1002749-01

FW-1001

5

FW Messages

FW-1001

Message

<label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the internal temperature of the switch has changed.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation. To prevent recurring messages, disable the changed alarm for this threshold. If you receive a
temperature-related message, check for an accompanying fan-related message and check fan
performance. If all fans are functioning normally, check the climate control in your lab.

FW-1002

Message

<Label>, is below low boundary (High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the internal temperature of the switch has fallen below the low boundary.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation. Typically, low temperatures mean that the fans and airflow of a switch are functioning
normally.

Verify that the location temperature is within the operational range of the switch. Refer to the hardware
reference manual for the environmental temperature range of your switch.

FW-1003

Message

<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the internal temperature of the switch has risen above the high boundary to a value that
might damage the switch.

Recommended

Action

This message generally appears when a fan fails. If so, a fan-failure message accompanies this
message. Replace the fan.

Advertising