Ham-1005 – Dell POWEREDGE M1000E User Manual

Page 564

Advertising
background image

542

Fabric OS Message Reference

53-1002749-01

HAM-1005

5

Fastboot

Giveup Master:SYSM

CP Faulty:SYSM

FirmwareDownload

ConfigDownload:MS

ChangeWWN:EM

Reboot:WebTool

Fastboot:WebTool

Software Fault:Software Watchdog

Software Fault:Kernel Panic

Software Fault:ASSERT

Reboot:SNMP

Fastboot:SNMP

Reboot

Chassis Config

Reboot:API

Reboot:HAM

EMFault:EM

Recommended

Action

Execute the errShow command on both control processors (CPs) to view the error log for additional
messages that may indicate reason for the switch restart.

HAM-1005

Message

HeartBeat Miss reached threshold.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that either the active CP Ethernet Media Access Controller (EMAC) or the standby CP is down.
The active CP will run a diagnostic test on EMAC and will wait for the standby CP to reset it if it is down.

Recommended

Action

No action is required.

Advertising