542

Fabric OS Message Reference

53-1002749-01

HAM-1005

5

•

Fastboot

•

Giveup Master:SYSM

•

CP Faulty:SYSM

•

FirmwareDownload

•

ConfigDownload:MS

•

ChangeWWN:EM

•

Reboot:WebTool

•

Fastboot:WebTool

•

Software Fault:Software Watchdog

•

Software Fault:Kernel Panic

•

Software Fault:ASSERT

•

Reboot:SNMP

•

Fastboot:SNMP

•

Reboot

•

Chassis Config

•

Reboot:API

•

Reboot:HAM

•

EMFault:EM

Recommended

Action

Execute the errShow command on both control processors (CPs) to view the error log for additional
messages that may indicate reason for the switch restart.

HAM-1005

Message

HeartBeat Miss reached threshold.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that either the active CP Ethernet Media Access Controller (EMAC) or the standby CP is down.
The active CP will run a diagnostic test on EMAC and will wait for the standby CP to reset it if it is down.

Recommended

Action

No action is required.