Fcr-1094, Fcr-1095, Fcr-1096 – Dell POWEREDGE M1000E User Manual

Page 394

Advertising
background image

372

Fabric OS Message Reference

53-1002749-01

FCR-1094

5

FCR-1094

Message

No Integrated Routing license present. EX-Port <ExPort> will not perform device
sharing with other Brocade Native mode fabric(s).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an EX_Port has been configured in Brocade Native mode. Device sharing will not occur
with other Brocade Native mode fabrics because the Integrated Routing license is not installed.

Recommended

Action

Install Integrated Routing license if device sharing is needed with other Brocade Native mode fabrics.

FCR-1095

Message

The EX-Port <ExPort> is configured in 'McData/Open' Mode which is no longer
supported, hence will be disabled next time port is offline and online.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an EX_Port has been configured in 'McData/Open' mode. Initially after HA failover, the
EX_Port will come up in McDATA mode. Further toggling will disable the port.

Recommended

Action

Remove the 'McData/Open' interop modes in all EX_Ports

FCR-1096

Message

Failed to allocate <data type> for <operation phase>: port <port number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the authentication process failed because the system is low on memory.

Data type is the payload or structure that failed to get memory.

Operation phase specifies which operation of a particular authentication phase failed.

Recommended

Action

Usually this problem is transient. The authentication may fail.

Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.